VCOM - Performance Ratio

Generally


The performance ratio is calculated from the yield of the system, the installed DC power and the irradiation at module plane. It provides an indication of how well the PV system can convert solar energy. A typical and good value is between 75 and 85% when viewed annually. Since there are many options for influencing the calculation of this value, the calculation can be adjusted using the editor in VCOM. The current IEC standard 61724-1 is used as the standard.

Necessary data

Energy sum defined as E_Z_EVU
Irradiance data from a sensor defined as G_M0 or satellite data

Calculation basis

The smallest time span of the performance ratio calculation is one day.
Monthly and annual values are aggregated accordingly and are weighted based on the projected energy.
For premium partners: Possibility to adjust parameters with the PR Editor

PR calculation in VCOM - standard method

The standard calculation of the performance ratio is calculated using the formula below (IEC 61724-1).





PR Berechnung in VCOM - PR Editor

(only VCOM Premium Partner)
The following parameters can also be adjusted using the PR Editor:


Source of the generated energy
Source of radiation: sensor or satellite data
Calculation space
Excluding the PR calculation on a daily basis for defined ticket causes
Define the type of data aggregation


Temperature compensation
required measured value is T_Mx calculated by a term:



Consideration of module degradation


Consideration of power control specifications


Exclude PR calculation explicitly via a ticket
(only VCOM Premium Partner)
The PR calculation can be excluded on a daily basis via a ticket for a certain period of time.
In this case, no PR is calculated and displayed.




In this case, the PR for the period February 21, 2021 to February 22, 2021 is not calculated and displayed.