WEBlog - Retrieve missing data in the VCOM (WEB'log)

WEBlog - Retrieve missing data in the VCOM (WEB'log)


1) If you have a park administration in VCOM and have the corresponding rights


- Click the symbol with the house  and then the symbol with the cogwheel 

- Then click on "Data" and "Import overview" in the new window

- On the button "System Selection", set the filter to "all systems" and click on "Start" on the right



- The corresponding data logger can be found by scrolling through the list (not identifiable)



- Two data tables are available with this data logger (Analog / Digital, String currents)

- Use button  to retrieve the data can be selected at the bottom right

- In the new window, the individual days for catching up can be clicked on



- Finally click at the bottom on 


- If the system includes several data loggers, the procedure must be carried out for each data logger



2.) You can copy the records from the CF memory card


- WEB'log disconnect the power

- Pull CF memory card out of slot (right side of WEB'log)

- Insert the CF memory card from the WEB'log into a USB memory card reader

- Connect memory card reader with USB to PC

- Access the new drive with the Explorer

- Mark the subdirectory DATA and press (Ctrl) (C) for copying

- Navigate to a drive on the PC, e.g. "C", and create a new directory

- In the new directory, press (Ctrl) (V) to insert

- The complete subdirectory DATA of the WEB'log is copied to the PC (this may take a few minutes, however)

- Mark the DATA directory and zip this directory, e.g. with "7-Zip"

https://www.7-zip.org

- Send the zip archive by e-mail to "technics@meteocontrol.com", subject "Data import", please include the S/N of the data logger (xxxxxx xxxx xxx) so that we can import the attached data, thank you

- Dismount the memory card reader from the PC and unplug the USB memory card reader

- Remove the CF memory card from the memory card reader and reinsert it in the WEB'log

- WEB'Log reconnect the power